
(PDF) VMware Certified Master Specialist 5V0-21.21 Exam and Certification Test Engine
Use 5V0-21.21 Exam Dumps (2022 PDF Dumps) To Have Reliable 5V0-21.21 Test Engine
VMware 5V0-21.21 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
NEW QUESTION 30
An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.
Which VMware product should the administrator install as the Kubernetes platform choice?
- A. VMware Tanzu Build service
- B. VMware Tanzu Data services
- C. VMware Tanzu Mission Control
- D. VMware Tanzu Kubernetes Grid
Answer: D
NEW QUESTION 31
Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?
- A. When a site is disconnected, the VM will continue to have access to its VMDK.
- B. Proper policies result in higher inter-site bandwidth utilization.
- C. Bandwidth is unnecessarily sent across the inter-site link.
- D. When a site is disconnected, the VM will lose access to its VMDK.
Answer: D
NEW QUESTION 32
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?
- A. All objects will remain accessible.
- B. All objects on the affected host will be lost.
- C. A rebuild of the affected objects will occur.
- D. The cluster will be partitioned and the vSAN host will need to be rejoined.
Answer: C
NEW QUESTION 33
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?
- A. A 16GB multiple-level cell (MLC) SATADOM device must be used.
- B. A 16GB single-level cell (SLC) SATADOM device must be used.
- C. A 4GB USB or SD device must be used.
- D. ESXi Hosts must boot from a PMEM device.
Answer: A
NEW QUESTION 34
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)
- A. Put the affected vSAN host into maintenance mode to physically replace the storage device.
- B. Replace the failed disk with a storage device that is identical in class and capacity.
- C. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
- D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
- E. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
- F. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.
Answer: A,B,C
Explanation:
If you upgrade the capacity device, verify the following requirements:
- Verify that the cluster contains enough space to migrate the data from the capacity device.
- Place the host in maintenance mode. See Place a Member of Virtual SAN Cluster in Maintenance Mode.
"Select the flash capacity device or magnetic disk, and click Remove selected disk(s) from disk group."
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-4E3390C1-6C50-49E5-AEB6-C9BC037979A1.html
NEW QUESTION 35
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)
- A. The vSAN Resync throttling is enabled.
- B. The vSAN policy protection level has changed from FTT=0 to FTT=1.
- C. The cluster DRS threshold has been set to Aggressive.
- D. The object repair timer value has been increased.
- E. There is a vSAN node failure.
Answer: A,B
NEW QUESTION 36
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?
- A. vSAN proactive tests haven't been run yet.
- B. vSAN network diagnostic mode is not enabled.
- C. vSAN performance verbose mode is not enabled.
- D. vSAN performance service is turned off.
Answer: D
Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.
NEW QUESTION 37
An architect is tasked to design a VMware Horizon Solution with vSAN. The architect needs to use a solution to host the user's profile shares in a highly available manner, and it must be guest OS independent.
Which solution will match these requirements?
- A. Cluster in a box
- B. iSCSI on vSAN
- C. Cluster out of the box
- D. NFS on vSAN
Answer: B
NEW QUESTION 38
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)
- A. Replace the failed disk with a storage device that is identical in class and capacity.
- B. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
- C. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
- D. Put the affected vSAN host into maintenance mode to physically replace the storage device.
- E. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
- F. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.
Answer: A,B,C
NEW QUESTION 39
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?
- A. Obtain additional free capacity from the existing FC storage.
- B. Obtain additional free capacity from the existing NAS storage.
- C. Create an HCI Mesh using the second cluster's datastore.
- D. Create an HCI Mesh using the first cluster's datastore.
Answer: B
NEW QUESTION 40
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?
- A. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.
- B. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
- C. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.
- D. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.
Answer: A
NEW QUESTION 41
An administrator has an absent capacity disk.
Which action, if any, should the administrator take to resolve the problem?
- A. Wait, and vSAN will rebuild it.
- B. Replace the faulty host.
- C. Verify the host is not isolated.
- D. Replace the faulty disk.
Answer: A
NEW QUESTION 42
data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?
- A. Enable IOInsight Metrics.
A minimum cluster of 2 vSAN ROBO nodes. - B. Enable performance services.
A minimum cluster of 6 vSAN nodes. - C. Enable host build reserve.
A minimum cluster of 4 vSAN nodes. - D. Enable operations reserve.
A minimum cluster of 3 vSAN nodes.
Answer: C
NEW QUESTION 43
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)
- A. Configure the new vSAN witness as a shared witness appliance.
- B. Configure the vSAN stretched cluster to use the new vSAN witness.
- C. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
- D. Deploy a new large vSAN witness appliance at the witness site.
- E. Add the new vSAN witness appliance to vCenter Server.
- F. Deploy a new extra large vSAN witness appliance at the witness site.
Answer: A,B,D
NEW QUESTION 44
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)
- A. Create an encryption storage policy
- B. Establish a trusted connection with the KMS
- C. Enable Data-In-Transit encryption first
- D. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned
- E. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
- F. Enable that the virtual machines are powered on
Answer: B,E,F
NEW QUESTION 45
An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the "Full-data migration" option.
What will happen after this action is taken?
- A. The host will enter in maintenance mode and only data with no redundancy will remain accessible.
- B. The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
- C. The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
- D. The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
Answer: B
NEW QUESTION 46
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)
- A. Promiscuous Mode
- B. MacLearning
- C. Jumbo Frames
- D. DVFiltering
- E. Forged Transmits
Answer: A,E
NEW QUESTION 47
......
5V0-21.21 Dumps Full Questions with Free PDF Questions to Pass: https://torrentpdf.practicedump.com/5V0-21.21-exam-questions.html