[Q84-Q101] CSDB by PCA Actual Free Exam Questions And Answers [UPDATED 2026]

Share

CSDB by PCA Actual Free Exam Questions And Answers [UPDATED 2026]

CSDB Questions Truly Valid For Your PCA Exam!

NEW QUESTION # 84
Rising damp is moisture that:

  • A. Enters through windows
  • B. Falls from the roof
  • C. Travels upward from the ground through capillary action in masonry
  • D. Is caused by condensation only

Answer: C


NEW QUESTION # 85
Penetrating damp is typically worse:

  • A. In buildings with cavity walls
  • B. In summer only
  • C. During dry weather
  • D. During and after periods of heavy rainfall, especially with wind-driven rain from exposed directions

Answer: D


NEW QUESTION # 86
The pattern of penetrating damp on internal surfaces typically shows:

  • A. Damp only in winter
  • B. Consistent tide marks
  • C. Damp patches that correspond to external defects and increase in size after heavy rainfall
  • D. Even coverage across walls

Answer: C


NEW QUESTION # 87
Cavity wall insulation problems related to penetrating damp can be minimized by ensuring:

  • A. Cavity ties are clear, insulation is correctly installed without bridging the cavity, and external envelope is sound
  • B. Cavity insulation fills the entire cavity
  • C. Insulation is in direct contact with external leaves
  • D. No inspection is done

Answer: A


NEW QUESTION # 88
When assessing rising damp, the surveyor must evaluate:

  • A. Age of building only
  • B. Construction material only
  • C. Height of damp, source verification, and rate of progression
  • D. Presence or absence of DPC only

Answer: C


NEW QUESTION # 89
According to Building Regulations Approved Document C, what is the primary requirement for buildings below ground level?

  • A. Thermal insulation only
  • B. Protection against moisture from the ground and from the atmosphere
  • C. Aesthetic protection only
  • D. Sound insulation

Answer: B


NEW QUESTION # 90
A commercial property has severe rising damp but alternative treatments (electro-osmotic, capillary breaks) cannot be installed due to structural constraints. The surveyor's recommendation should include:

  • A. Accepting permanent damp
  • B. Only internal cosmetic treatments
  • C. Conventional chemical DPC installation as appropriate method, with realistic expectations regarding moisture reduction timescale
  • D. Demolition of the building

Answer: C


NEW QUESTION # 91
Common sources of penetrating damp include:

  • A. New buildings only
  • B. Interior condensation only
  • C. Rising damp only
  • D. Defective guttering, broken downpipes, failed mortar joints, and cracked masonry

Answer: D


NEW QUESTION # 92
Under COSHH regulations, before using hazardous substances on site, the employer must:

  • A. Assume no risk
  • B. Only provide PPE
  • C. Simply provide the product
  • D. Assess the risk and implement control measures

Answer: D


NEW QUESTION # 93
The relationship between temperature and condensation risk is:

  • A. Cold surfaces (below dew point) increase condensation risk regardless of humidity
  • B. Temperature does not affect condensation
  • C. Irrelevant
  • D. Only high temperatures cause condensation

Answer: A


NEW QUESTION # 94
Personal Protective Equipment (PPE) should be provided:

  • A. As the primary control method
  • B. As the last resort when all other control measures are inadequate
  • C. Never
  • D. Only if employees request it

Answer: B


NEW QUESTION # 95
When moisture meter readings are inconsistent across multiple measurements in the same wall section, the surveyor should:

  • A. Average the readings uncritically
  • B. Report only one reading
  • C. Report only the highest reading
  • D. Investigate causes of variation (salts, temperature, material differences), document findings, and note limitations in interpretation

Answer: D


NEW QUESTION # 96
A property has rising damp. The surveyor identifies that previous treatment involved only internal moisture- blocking paint without chemical DPC installation. The reason this was ineffective is:

  • A. Paint prevented evaporation, potentially increasing internal damp
  • B. Paint was correct approach
  • C. Paint does not address the moisture source (ground moisture); treating the source with DPC is required
  • D. Rising damp cannot be treated

Answer: C


NEW QUESTION # 97
External liquid-applied membranes to prevent penetrating damp should:

  • A. Be applied without preparation
  • B. Never be used
  • C. Be painted on all masonry
  • D. Be specified only for areas of defect, with proper preparation and following manufacturer guidance for substrate conditions

Answer: D


NEW QUESTION # 98
The Health and Safety at Work etc. Act 1974 places responsibility for workplace safety primarily on:

  • A. The employer
  • B. The Health and Safety Executive only
  • C. Building owners
  • D. Individual employees only

Answer: A


NEW QUESTION # 99
When treating penetrating damp in cavity walls, the surveyor should consider:

  • A. Removing the cavity
  • B. Only external repairs
  • C. Cavity integrity, insulation condition, external envelope condition, and cavity drainage provisions
  • D. Only internal treatments

Answer: C


NEW QUESTION # 100
When reporting condensation, the surveyor should advise on:

  • A. Ventilation improvements, heating adequacy, moisture generation control, and thermal insulation
  • B. Only dehumidifiers
  • C. Only moisture removal
  • D. Only mould cleaning

Answer: A